International Masonry Institute
Description
IMI Detail 02.010.0401. This detail shows an 8” (nominal) split face concrete masonry (CMU) wall, window sill condition. Flashing is provided below the masonry sill, returning vertically at the end termination to form and end dam. Ladder-type horizontal joint reinforcement is placed at 16” o.c. vertically in the wall, or as required. This detail is intended for the use of industry professionals who are competent to evaluate the significance and limitations of the information provided herein. This detail should not be used as the sole guide for masonry design and construction, and IMI disclaims any and all legal responsibility for the consequences of applying the information. For more information contact sconwell@imiweb.org. #AIA #BAC #bearing #block #brick #bricklayer #cavity #CMU #concrete_masonry #Conwell #end_dam #flashing #green #grout #grouted #highperforming #HJR #IMI #IUBAC #loadbearing #masonry #MDS #mortar #overlap #rebar #reinforced #reinforcement #reinforcing #sill #single_wythe #splice #split_face #structural #sustainability #sustainable #wall #wall_tie #weep_holes #weep_vents #weeps #window_sill
Default Title