Foundation Dowel Alignment

Foundation Dowel Alignment

International Masonry Institute
Description
IMI Detail 02.010.0301. This detail shows a concrete masonry (CMU) wall in partial longitudinal section. In case the foundation dowels do not coincide with the center of the CMU cells, dowels may be bent 1” laterally for every 6” vertically. Vertical reinforcement overlaps the dowels to achieve sufficient development strength per structural design. This detail is intended for the use of industry professionals who are competent to evaluate the significance and limitations of the information provided herein. This detail should not be used as the sole guide for masonry design and construction, and IMI disclaims any and all legal responsibility for the consequences of applying the information. #AIA #anchor #anchored #anchors #BAC #bearing #block #brick #bricklayer #cantilever #cavity #CMU #concrete_masonry #Conwell #development #dowel #dowels #foundation #green #grout #grouted #highperforming #HJR #IMI #IUBAC #lap #loadbearing #masonry #MDS #mortar #overlap #rebar #reinforced #reinforcement #reinforcing #splice #structural #sustainability #sustainable #wall #wall_tie