IMI Detail 02.010.1311. This detail shows a vertical control joint at intersecting CMU walls. The debonded shear anchor ties the walls together, but also allows the intersecting wall to shrink back from the continuous wall, as the anchor moves along its track. There is horizontal joint reinforcement at 16" o.c. vertically in the wall (not shown), interrupted at the CJ. This detail is intended for the use of industry professionals who are competent to evaluate the significance and limitations of the information provided herein. This detail should not be used as the sole guide for masonry design and construction, and IMI disclaims any and all legal responsibility for the consequences of applying the information. #AIA #air_barrier #anchor #BAC #block #brick #bricklayer #cavity #CJ #CMU #control_joint #Conwell #debonded_shear_anchor #drainage #flashing #gasket #green #grout #highperforming #IMI #intersecting #IUBAC #masonry #MDS #mortar #movement_joint #sustainability #sustainable #wall_tie #weeps